Rubicon's flow meters have been developed specifically to meet the demanding needs of the irrigation industry - providing accurate and reliable operation in harsh and remote environments.
Rubicon's SlipMeter™ is an integrated solution that includes flow meter, control gate, communications, SCADA, solar power, local display pedestal and management software -providing a cost-effective alternative to separate component solutions.
Utilizing Sonaray™ acoustic array measurement technology they uniquely provide accurate measurement across both high and low flow ranges.
Rubicon specifies SlipMeter™ flow measurement accuracy of ±2.5% in the laboratory and ±5% in the field
The SlipMeter's™ accuracy has been verified by independent laboratory and field testing.
The SlipMeter™ features Sonaray™ acoustic array flow measurement technology, which Rubicon developed to provide accurate and reliable flow measurement under the harsh conditions experienced in the irrigation industry.
A development of ultrasonic flow measurement, Sonaray™ acoustic array flow measurement is a new innovation developed by Rubicon. It employs concepts found in medical imaging in which an array of acoustic transducers is used to provide a three-dimensional image of a medium.
This technology enables measurement of very low velocities, meaning that both high and low flows can be accurately measured in a single meter.
Additionally it provides accurate flow measurement even in the presence of severe flow disturbances.
| Flow measurement accuracy | ±2.5% in the field |
| Minimum flow where accuracy is guaranteed | 0.4cfs |
| Maximum flow where accuracy is guaranteed | 16.5 cfs |
| Power supply | 12VDC self-contained battery, charged from solar panel, or mains supply |
| Data interface | Local display, modbus serial, data radio |
| Sampling frequency | 100ms |
| Calibration method | Factory pre-calibrated and internal self-calibrating quartz timer |